The below settings are to be used for a common NH3 applicator configuration. Most commonly a Raven 440/450 with NH3 Fast Valve Accuflow systems will use these settings. If your AC110 came with a kit specific to your sprayer, please look to see if there is another configuration chart for your model before using these configurations.
Note: Click on any of the Menu/Button titles in the table below, for more information on that subject.
| Menu/Button | Suggested Setting | Notes |
| New implement Profile - | ||
| Name: | Implement Specific | Required |
| Mount Type: | Implement Specific | Required |
| Implement Settings - | ||
| Width: | Implement Specific | Required |
| Implement Configuration - | ||
| Left Offset: | Implement Specific | Not Required |
| Right Offset: | Implement Specific | Not Required |
| Axle Position: | Implement Specific | Required |
| Working Point: | Implement Specific | Required |
| Skip/Overlap: | User Preference | Not Required |
| Operation: | Tilling | Required |
| External Switches: | Do not check the box | This does not need to be checked if using the OBK switchbox. |
| Controller Type: | AC110 | Required |
| Section Valve: | Motor/SOL 1 Direct | Required |
| Number of Sections | 1 | Required |
| Section Location/Width: | Implement Specific | Not Required |
| Group Sections: | User Preference | Not Required |
| Overlap Settings - | ||
| Coverage: | 95% or Less | Can be lowered to User preference |
| Overlap Tolerance: | 2 FT | Not Required but suggested |
| Coverage at Boundaries: | Match Coverage Above | Not Required but suggested |
| On Time: | 1.5 s | User will need to adjust to there preference |
| Off Time: | .5 s | User will need to adjust to there preference |
| Test Sections: | Diagnostic Use Only | |
| Rate Control settings - | ||
| Controller Type: | AC110 | Required |
| Remote Master: | Do not check the box | This does not need to be checked if using the OBK switchbox. |
| Rate Valve: | Motorized direct | Positive Close Needs to Be On |
| Open/Close Valve: | Diagnostic Use Only | |
| NH3 | On | |
| Parameters - | ||
| On Look Ahead: | 1.0 s | Only for RX Mapping |
| Low Flow Setting: | 0 | Typically not used for NH3 |
| Valve Advance: | 0 | Typically not used for NH3 |
| Calibration - | ||
| Meter Calibration: | Calibration number will be on the flow meter | Required |
| Pressure 1 Calibration: | Not used in this application | |
| Pressure 2 Calibration: | Not used in this application | |
| System Calibration: | Auto Calibration | |
| Calibration Values- | Note: Outback suggest running the system Calibration before changing any calibration values. Below are examples of a calibrated system. | |
| K : | 0.2816 | |
| Trigger : | 300 | |
| Flow Range : | 3000 | |
| Min PWM : | 3 | |
| Time Response : | 8 | |
| Max PWM : |
100 |
|
| Calibration | ||
| eTurns Calibration | See eTurns calibration | |