Symptom: User cannot perform the calibrations on the R Series John Deere with eDriveX.
Cause(s):
1. The console must be "Unlocked" for the John Deere R Series tractors through Outback Guidance Customer Service.
2. The user needs to contact John Deere and order an activation code to unlock compatibility. The order code is 0260PC,1001.
3. The user has the wrong "Valve Type" selected from the calibration menu.
Resolution(s): Ensure the user has the S3, or MAX unlocked for the JD R Series, as well as, the JD code purchased and entered on the JD tractor management system.
If the above has been met, the user MUST select "JD AutoTrac CAN" as the valve type for the R Series JD. The "JD AutoTrac" valve type is used for all other steer ready JD platforms.